Rinnai Heating Specication Guide 02-13 | 5
Choosing the right type of heating
Considerations such as geographical location, room size, room insulation, running costs,
and functionality versus aesthetics all play a part in choosing the right heating solution.
Geographical location
Where you live in New Zealand
can determine the type of
heating solution you choose.
Use the diagram below to work
out which climate zone you are
in.
Room size
Consider the whole area you
need to heat. This should
include adjacent rooms through
permanently open doorways
and hallways.
A useful guide when calculating
the size of heater you need is
to measure the room volume in
metres (length x width x height)
and divide by 20 to get the kW
rating of the appliance needed.
If there are any heat loss factors
you will need to increase the kW
rating slightly to compensate.
Heat loss
Heat loss factors include:
- no ceiling or wall insulation
- no carpets on floors
- no curtains
- window area >15 m²
- ceiling height > 2.4 m²
- building on poles or piles
Also consider how good the
insulation is in the building.
Running costs
Upfront purchase costs should
be considered in conjunction
with the ongoing running costs
of a heating solution. To work
out what these may be refer to
appendix 1 on page 30.
Functionality vs. aesthetics
Additional considerations are
based on functionality, the size
and look of the heater, and
where it is likely to be installed.
For example are timers and
a remote important, or is
operating simplicity a key
factor?
HEATING AREA (based on a standard ceiling height of 2.4 m)
Warm zone Medium
zone
Cool Zone
Energysaver 309FT 45 m
2
31 m
2
26 m
2
Energysaver 559FT 77 m
2
53.5 m
2
45.5 m
2
Energysaver 561FT 70 m
2
48 m
2
41 m
2
Energysaver 1004FTR 119 m
2
82 m
2
69 m
2
Portable Convector Dynamo 471* 51.5 m
2
45 m
2
38 m
2
Portable Convector Avenger 671* 95 m
2
80 m
2
70 m
2
Indoor Super Ray 16** 19 m
2
19 m
2
19 m
2
Indoor Super Ray 24** 28 m
2
28 m
2
28 m
2
Indoor Super Ray 40** 47 m
2
47 m
2
47 m
2
Outdoor Super Ray 23 m
2
23 m
2
23 m
2
Rinnai iHeat 333 m² 285 m² 250 m
2
* These heaters are subject to a minimum room size, refer specification pages for further
detail
** The Indoor Super Ray heaters are for commercial and industrial use only
Warm
Medium
Cool