12 | Rinnai Heating Specication Guide 02-13
Energysaver ueing guidelines
It is the responsibility of the
installer to ensure that the
appliance is provided with an
effective flue. Some guidelines
to assist with flue design are
listed below. These must be
read and modified as necessary
with reference to the particular
installation.
All Rinnai Energysavers must
be installed with an approved
Rinnai flue system. Approved flue
components are detailed in this
guide.
Clearance to combustibles
All Energysaver flueing
components have zero clearance
EXCEPT for the elbow section
of the ESKIT03, and ESELBOWB.
These components require a
minimum clearance of 25 mm
from combustible materials.
Condensate
A condensate trap is required for
any vertical flue installations to
ensure condensate generated
during combustion is trapped
and drained to prevent it from
entering the combustion
chamber.
For horizontal and down and
out installations there must be a
continuous fall of at least 2 °. This
equates to approximately
20 mm per metre to the
termination point to drain
condensate. For standard direct
flueing, the Rinnai mushroom
flue kits have an inbuilt 2 ° fall.
Flue terminal locations
Must be compliant with
AS/NZS 5601.1.
• Do not flue into natural
draught flues or fireplaces.
• Do not flue into other
rooms, roof spaces, or under
floor spaces.
Flue terminal must be positioned
away from flammable materials.
In areas subject to heavy snowfall,
keep snow clear of the flue
terminal at all times.
Flashings
Flashings are not part of the flue
kit and must be specified.
Vertical terminations: Flue
cowl clearance
To ensure products of
combustion are cleared,
adequate clearance from the
building is required.
The flue cowl should have a
500 mm clearance from any
part of the building. This also
applies to steeped and pitched
roofs which should be clear of
the ridge line. Lesser clearances
may provide perfectly adequate
flue systems depending on the
installation. Minimum clearances
are shown in AS/NZS 5601.1.
Maximum flue length and
number of bends
Max. flue length = 9 m
Max. number of bends = 3
One 90 ° bends equals 1 m. For
every 90 ° bend the overall length
must be reduced by 1 m. For
example, if an installation has
three 90 ° bends, the maximum
flue length can be 6 m.
The flue transition connection
for the ESKIT03 and ESELBOWB is
counted as a 90 ° bend.
Every Energysaver heater requires a flue system that will draw effectively and clear flue
products safely under all potential wind and climatic conditions.
Minimum clearance
500 mm to nearest
part of roof
Elbow section