Fault Codes
A fault code will flash on the unit when a fault occurs. The unit will stop operating.
Operation intervention is required for all codes EXCEPT a code 11.
To view the last nine fault codes, with the unit OFF, press the UP, DOWN, and, ECONOMY buttons simultaneously
CODE PROBABLE CAUSE COMMENTS
11
Ignition or Flame failure
Flame current inadequate; Unit will attempt to relight (see Manual-Restart Feature)
14
Overheat Safety Device Overheat safety bimetal(s) or thermal fuse has activated
16
Over temperature cut off Room temperature is sensed as being above 104°F for longer than 10 minutes
31
Room temperature thermistor disconnection Room temperature thermistor open circuit
32
Room temperature thermistor short circuit Room temperature thermistor wire shorted or touching bare metal
33
High limit thermistor disconnection High limit thermistor open circuit
34
High limit thermistor short circuit High limit thermistor shorted or touching bare metal
49
Pressure sensor disconnect or breakdown Check sensor connection to PCB & hoses to blower motor
53
Abnormal spark sensed Spark not sensed correctly
61
Abnormal combustion fan motor rpm Fan speed not achieved within time or goes over speed
62
Convection fan failure Ensure convection fan can turn freely
70
ON/OFF switch failure ON/OFF switch connects continuously for more than 15 seconds
71
Solenoid valve check Solenoid valve(s) (SV1 & SV2) signal and response signal are different
72
Flame rod failure PCB fails to sense microamps within 20 seconds
73
Communication failure Data transfer within PCB fails
99
Flue block or venting disconnect Check intake and exhaust inside and outside for blockage or freezing