Rinnai RINV70R-A Installationsanleitung Seite 1

Stöbern Sie online oder laden Sie Installationsanleitung nach Split-System-Klimaanlagen Rinnai RINV70R-A herunter. Rinnai RINV70R-A Installation guide [en] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 19
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
• Current AS/NZS 3000
All applicable local rules and regulations including local OH&S requirements
Manufacturers Installation Instructions
This system must be installed, commissioned and serviced by an Authorised Person.
Seitenansicht 0
1 2 3 4 5 6 ... 18 19

Inhaltsverzeichnis

Seite 1 - • Current AS/NZS 3000

•• Current AS/NZS 3000•All applicable local rules and regulations including local OH&S requirementsManufacturer’s Installation InstructionsThis sy

Seite 2 - CONTENTS

1.Please read the instructions carefully before installation of the air-conditioner.2.The installation should be carried out by only authorised person

Seite 3 - Safety Precautions

15cm 15cm Above 10cmAbove 60cmAbove 200cmAboveAboveAbove 30cmThe distance between indoor and outdoor unit should be 5 meters and pipe length can go up

Seite 4 - WEEE Warning

●First make changes to wall and make sure that is hard and secure. Using four + type screws to fasten the installation board onto the wall. Use

Seite 5 - Name of Each Part

600X250X490390290Outdoor Unit Size (mm)A (mm) B (mm)540326800X300X690(590)539287760X260X540606354900X330X860535 353967X380X805Check the water discharg

Seite 6

- 12 -Pipe connection● Connect the pipe to the unit: point to the center of pipe and fasten by wrench until it is tightly fastened, the

Seite 7 - Notices

Expelling the air in the pipes and the indoor unit★Expelling the air: humid air in the refrigerating system might cause trouble of compressor.● Take o

Seite 8 - Troubleshooting

- 14 -● ● ● The grounded wire connection: 1.loosen the grounded screw of electric bracket. 2.Connect the grounded wire with the grounded screw

Seite 9 - Troubleshooting

NOTE:※Connect the grounded wire correctly, otherwise will cause the malfunction of some electrical componet and shock or fire indeed.※Don't r

Seite 10 - Installation Guide

● Make sure that pipes and wires are connected.● Make sure that liquid side valve and air side valve both are completely open.1. The connection of

Seite 12

CONTENTSSafety PrecautionsName Of Each PartWEEE Warning134566891011121416162CommissioningPacking listOperationNotices Care and Maintenance Troublesho

Seite 13 - Check the water discharge

WARNINGSafety PrecautionsIncorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following ind

Seite 14 - Pipe connection

1.Don t install the indoor unit in direct sunlight.2.Don t block air inlet or air outlet, otherwise, the cooling or heating capacity will be weaken

Seite 15

Indoor UnitNote:1.If the power supply (comes directly) from outdoor unit, you can find the power supply cord is fitted in the outdoor unit.2.. The d

Seite 16 - Electrical connection

3OperationManual operation★Manual operation☆When the remote controller does not work or can not be found, please follow these steps:1.As the unit is o

Seite 17 - Blue= Zero line

★In order to use the air conditioner properly, please refer to its working temperature range. Otherwise, indoor unit automatic protection function may

Seite 18 - Packing list

Care and Maintenance Troubleshooting 1.Turn off the air-conditioner and remove the electrical plug from the outlet.2. soapy water.Wipe the indoor u

Seite 19

PhenomenonTroubleshootingRemote controller is not workingIs the remote controller out of effective distance to the indoor unit?Is the battery flat?Are

Kommentare zu diesen Handbüchern

Keine Kommentare