Energysaver RHFE-556FTRCustomerpage 2Installerpage 21CONTENTSWarranty ...1Layout of appliance...2Features...
– 9 –OPERATING YOUR NEW RHFE-556FTR TO OPEN THE CONTROL PANELLift lightly in the centre of the lid where there isa catch. The control panel lid will
– 10 – ROOM TEMPERATURE ADJUSTMENT ECONOMY MODEThe room temperature and pre-set temperatures can only be displayed and adjusted when the heater isru
– 11 – CHILD PROOF LOCK AUTO COMFORTA room temperature sensor located at the rear of the appliance is continuously monitoring the temperatureof the
– 12 – FAN FILTERTo protect the room air fan from dust particles or lint, afilter is situated at the rear of the appliance. Whenthis filter becomes
– 13 –SETTING THE CLOCKThis Heater has an Integral Time Clock but can also be installed as part of a centrally controlled Time ClockSystem.To set-up t
– 14 –PROGRAMMING THE TIMER(S)Before programming the Timers you must ensure that the clock has been set to the correct time. See page 13.TIMER 2 is p
– 15 –OPERATING THE TIMER(S)Before operating the Timer(s), the clock time must be correct, and a starting time and finishing time forthe Timer(s) must
– 16 –PRE-HEATThe Pre-heat function will heat a room to the pre-set temperature by the programmed On Time.1This function operates automatically in con
– 17 –OVERRIDE FUNCTIONUSING THE REMOTE CONTROLThis function is intended to be used to manually override the current operation of the heater, Forexam
– 18 –CARING FOR YOUR NEW RHFE-556FTRThis appliance is controlled by a micro computer. If there is something wrong with the appliance thenit will sto
– 1 –RINNAI WARRANTY OF QUALITYAs the purchaser of this high quality model RHFE-556FTR product you are provided with the followingwarranty:Free PartsH
– 19 –PRE-SERVICE CHECKBefore asking for a service call please check the following points.These points are part of the normal operation of the unit.
– 20 –ERROR MESSAGESThe Energysaver 556FTR has the ability to check its own operation continuously. If a fault occurs, anError Message will flash on
– 21 –INSTALLATION INSTRUCTIONSIMPORTANT SAFETY INFORMATION1. Gas Safety (Installation & Use). Regulations 1998 are the ‘Rules in Force’.In your
– 22 –INSTALLATION INSTRUCTIONSSPECIFICATIONInput 6.4Kw (21840 Btu/h) Burner: Stainless Bunsen TypeIgnition: Continuous Spark Gas Inlet: 1/2 inch BSP
– 23 –LOCATIONWhen positioning the heater the main pointsgoverning the location are:1. Flueing2. Warm air distributionThis heater must not be installe
– 24 –LOCATIONDo not flue into natural draught flues or fireplaces,this unit can only be used with one of the six typesof Rinnai flue kits.Do not flue
– 25 –POSITIONING THE FLUE TERMINALOHNNMQMHKBPQQIFLJGCAID,EDimensionABCDEFGHIJKLMNOPQTerminal PositionDirectly below an opening, air brick, opening wi
– 26 –LOCATIONDo not install the heater in an unusually dusty area.Use a flue guard if the terminal is easily accessibleto children.Check local regula
– 27 –SLEEVE AND MANIFOLD INSTALLATIONMETHOD FOR STANDARD WALLS1. Dis-assemble Manifold from Sleeve.The flue consists of 3 parts, sleeve, insideconnec
– 28 –SLEEVE AND MANIFOLD INSTALLATIONMETHOD FOR STANDARD WALLS5. Check rubber seal is in place on terminal.6. Installation of TerminalFrom outside, i
– 2 –GETTING TO KNOW YOUR NEW RHFE-556FTRREMOTE CONTROLBRACKETROOMTEMPERATURESENSORGAS CONNECTIONELECTRICAL CORDHUMIDIFIER TRAYBuilt into the warm air
– 29 –FITTING UNITAIR INLET HOSELOCKING CLAMP, SCREW CLAMP ANDINSULATION.The following components can be fitted by reachingdown the rear of the applia
– 30 –CONNECTING GAS AND ELECTRICAL SERVICES1. GAS CONNECTION.Purge any air or swarf from the gas line. Connect up the appliance to the gas supply us
– 31 –TESTINGPRESSURE CHECKING PROCEDURECaution – 230V inside appliance1. Check that SW6 (Dip switches) are correct for the gastype for which the appl
– 32 –FITTING TOP SPACER + WALL CLIP SECURE HEATER TO WALLFix angle bracket to back spacer with screwsprovided.Fix wall bracket to wall, so that the
– 33 –BLOCK AND WIRING DIAGRAMWIRING DIAGRAMBLOCK DIAGRAMSW6, DIP SWITCHTB1SUB-P.C.BSW1 FM, ADJUST SWITCH〔Hi〕 SW2 FM, ADJUST SWITCH〔Lo〕 SW3 POV, P
– 34 –• This extension set is to be used for installations requiring extra distance.MAXIMUM FLUE LENGTH 4.5m WITH 3 ELBOWS NAMES AND NUMBERS OF PARTS
– 35 – TYPES COMPATIBLE WITH EXTENSION KITRHFE-556FTR/556TINSTALLING AN EXTENSION KITInstalling an extension kit requires construction of an air line
– 36 –1. How to connect exhaust pipesTo connect the exhaust pipes, fit the male end into the female end and clamp with pipe stopper A toprevent slippi
– 37 – CAUTIONS1. Maximum extendable lengthFOR BEST ROOM AIR HUMIDITY, KEEPWATER IN THE HUMIDIFIER TRAY.2. To prevent water condensationCondensed wat
– 38 –4. Wherever the air intake hose and exhaust piperun sideways, try to have the exhaust pipe ontop (to prevent the air intake hose from saggingont
Child LockTimer 1EconomyTimer 2 OverrideAMPMSet RoomTemp・ TimeSet timesClockTimer 1Timer 2Filter on offON / OFFON・ – 3 –CONTROL PANEL LAYOUTECONOM
– 39 –556F-219101 / 06DIMENSIONSSERVICE CONTACT POINT30050214R279R206217 245632750WALL OPENING RANGEAIR SUPPLY CONNECTION5542802807785165GAS CONNECTIO
– 4 –REMOTE CONTROLONOFFOFF BUTTONStops heater manually.TEMPERATUREADJUSTMENTIncreases or decreasesthe temperature setting. ON BUTTONOper
– 5 –FORCED FLUE SYSTEM PUSH BUTTON IGNITIONAir for combustion is taken from outside theroom and the flue products are exhaustedoutside, keeping the r
– 6 –MEMORYThe micro-computer records selected pre-set temperatures, the times programmedinto Timers as well as operating theEconomy and Intelligent m
– 7 –SAFETY POINTSDo not restrict the warm air discharge byplacing articles in front of the heater.This appliance must not be used for anypurpose othe
– 8 –SAFETY POINTSKeep flammable materials, trees, shrubs, etc,away from the flue terminal.Do not allow anyone to post articles throughthe louvres.LPG