Rinnai FC824 Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Raumheizungen Rinnai FC824 herunter. Rinnai FC824 Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 44
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Gas Fan Convecon Heater
Installaon and Operaon Manual
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other
appliance.
BEFORE OPERATING smell around the appliance for gas. Be sure to smell next to the oor because some
gas is heavier than air and will sele on the oor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instrucons.
If you cannot reach your gas supplier, call the re department.
Installaon and service must be performed by a qualied installer, service agency, or gas supplier.
If the informaon in these instrucons is not followed exactly, a re or explosion
may result causing property damage, personal injury or loss of life.
WARNING
READ ALL OF THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR OPERATING THIS HEATER.
This manual provides informaon on the installaon, operaon, and maintenance of the heater. For proper
operaon and safety, it is important to follow the instrucons and adhere to the safety precauons.
A licensed professional must install the fan convecon heater according to the exact instrucons within this
manual.
The consumer must read the enre manual to properly operate the heater and for instrucons on regular
maintenance required to be performed.
ANS Z21.11.2
FC510 ................... (RCE-391A)
FC824 ................... (RCE-691TA)
This is an unvented gas-red heater. It uses air (oxygen) from the room in which it is installed. Provisions for
adequate combuson and venlaon air must be provided. Refer to page 6 of this manual.
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
This appliance may be installed in an aermarket, permanently located, manufactured (mobile) home, where
not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rang plate. This appliance is not eld
converble for use with other gas types.
Service should be performed only by a licensed professional.
Seitenansicht 0
1 2 3 4 5 6 ... 43 44

Inhaltsverzeichnis

Seite 1 - Gas Fan Convecon Heater

Gas Fan Convecon Heater Installaon and Operaon Manual — Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this

Seite 2 - Important Safety Informaon

10 Fan Convector Manual Gas Fan Convecon Heater Operaon Instrucons Important Facts about your Gas Fan Convecon Heater Thank you for purchasing a

Seite 3 - CAUTION

Fan Convector Manual 11 Consumer Operaon Guidelines for the Safe Operaon of your Fan Convecon Heater FOR YOUR SAFETY READ BEFORE OPERATING A.

Seite 4 - Installaon Instrucons

12 Fan Convector Manual WARNING  Before operang, smell all around the appliance area for gas. Be sure to smell next to the oor because som

Seite 5 - Prepare for installaon

Fan Convector Manual 13 Operang Instrucons FC510 Control Panel Layout Auto O Indicator Indicates the thermo

Seite 6 - Clearances

14 Fan Convector Manual Operang Instrucons FC824 Control Panel Layout Auto O Indicator Indicates the thermost

Seite 7 - Gas Connecon

Fan Convector Manual 15 Operang The Heater TURNING ON: Press the ON/O

Seite 8 - Manual gas

16 Fan Convector Manual Economy Mode: Press the Economy buon to start

Seite 9 - Specicaons

Fan Convector Manual 17 Operang the Timer(s) (FC510): Press the On Timer buon . The On Time indicator will illuminate and the Combuson indicator

Seite 10 - Operaon Instrucons

18 Fan Convector Manual Seng the Clock: (FC824) When the appliance is rst plugged in and then turned on, the digital display will show “- -:- -”

Seite 11 - WARNING

Fan Convector Manual 19 Operang the Timer(s) (FC824): NOTE Before operang the Timer(s), the clock me must be

Seite 12

2 Fan Convector Manual Table of Contents This is the safety alert symbol. This symbol alerts you to potenal hazards that can kill or hurt you and

Seite 13 - Operang Instrucons

20 Fan Convector Manual The appliance must be inspected annually by a licensed professional. Repairs and maintenance should be performed by a licen

Seite 14

Fan Convector Manual 21 Clean as follows: 1. Turn heater o. Unplug electrical cord and allow to cool for 1 hour. 2. Remove the louver assembly.

Seite 15 - Operang The Heater

22 Fan Convector Manual

Seite 16

Fan Convector Manual 23 1. Conrm that the heater is properly installed. See Installaon secon. 2. Make sure the gas valve on the LP gas bole or

Seite 17

24 Fan Convector Manual Diagnosc Codes This heater has the ability to check its own operaon connuously. If a fault occurs, an Error Message will

Seite 18

Fan Convector Manual 25

Seite 19

26 Fan Convector Manual

Seite 20 - Required Maintenance

Fan Convector Manual 27 Parts Breakdown FC510

Seite 21

28 Fan Convector Manual Parts Breakdown FC510

Seite 22

Fan Convector Manual 29 Parts Breakdown FC510

Seite 23

Fan Convector Manual 3 CAUTION  Do not install this appliance above 2,000.  Do not block the warm air discharge. Do not allow anyone to

Seite 24 - Diagnosc Codes

30 Fan Convector Manual Parts Breakdown FC510

Seite 25 - Electrical Diagram FC510

Fan Convector Manual 31 Parts Breakdown FC510

Seite 26 - Electrical Diagram FC824

32 Fan Convector Manual NO PART NAME PART NUMBER QTY. 001 FRONT PANEL 909000001 1 003 LOUVER ASSEMBLY 909000002 1 005 REAR PANEL 909000

Seite 27 - Parts Breakdown FC510

Fan Convector Manual 33 NO PART NAME PART NUMBER QTY. 135 BURNER LID 906000012 1 136 THERMOCOUPLE BRACKET-A 909000016 1 137 THERMOCOUP

Seite 28

34 Fan Convector Manual Parts Breakdown FC824

Seite 29

Fan Convector Manual 35 Parts Breakdown FC824

Seite 30

36 Fan Convector Manual Parts Breakdown FC824

Seite 31

Fan Convector Manual 37 Parts Breakdown FC824

Seite 32 - Parts List for FC510

38 Fan Convector Manual Parts Breakdown FC824

Seite 33 - Fan Convector Manual 33

Fan Convector Manual 39 NO PART NAME PART No. QTY. 001 FRONT PANEL 909000025 1 003 LOUVER ASSEMBLY 909000026 1 005 REAR PANEL 9090000

Seite 34 - Parts Breakdown FC824

4 Fan Convector Manual A licensed professional must install the appliance, inspect it, and leak test it before use. The warranty will be voided due

Seite 35

40 Fan Convector Manual NO PART NAME PART No. QTY. 130 CABLE CLIP CP-90125-4 2 131 LID 909000013 1 132 HEAT SHIELD 906000011 1 133 S

Seite 36

Fan Convector Manual 41 State of California: California law requires this noce to be provided: California Proposion 65 lists chemical substanc

Seite 37

42 Fan Convector Manual Consumer Support Consumer Support Warranty Informaon Limited Warranty

Seite 38

Fan Convector Manual 43 PRIVACY NOTICE: Rinnai somemes shares customer contact informaon with businesses that we believe provide products

Seite 39 - Parts List for FC824

900000001 1/2014 Rinnai America Corporaon • 103 Internaonal Drive, Peachtree City, GA 30269

Seite 40 - 40 Fan Convector Manual

Fan Convector Manual 5 Prepare for installaon Parts included Tools needed Materials needed  Gas Fan Convecon Heater  Anchors  Screws  Manual

Seite 41 - State Regulaons

6 Fan Convector Manual Determine Installaon Locaon  The heater must not be installed in a conned space or unusually ght construcon unless

Seite 42 -

Fan Convector Manual 7 Gas Connecon 1. Aach 2 xing plates to the boom of the base plate before connecng the gas. 2. The gas sup

Seite 43

8 Fan Convector Manual Electricity The heater requires 120 VAC, 60 Hz power from a properly grounded circuit. Plug the 6.5 foot (2 meter) long power

Seite 44 - RC-691-41X01(00)

Fan Convector Manual 9  Overheat Switch: The appliance will automacally shut down when the appliance exceeds a predetermined temperature. Dete