Symmetry RDV3610
Installation Manual
Appliance (including ue) is installed after framing and before cladding. Rinnai strongly
recommend appliance is fully tested before any cladding materials are applied.
Cladding must be installed up to the ange and not over it. Any overhang will alter the
performance of the appliance and cause an unsafe situation.
Appliance must be installed with a Rinnai supplied ue system.
Installation may require two people due to the size and weight of the appliance.
Appliance must be installed, commissioned and serviced by a licensed tradesperson in
accordance will all applicable local rules and regulations.
Not intended as a replace insert
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - Symmetry RDV3610

Symmetry RDV3610Installation ManualAppliance (including ue) is installed after framing and before cladding. Rinnai strongly recommend appliance is fu

Seite 2 - Contents

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1010Building the frameUsing the dimension drawing below and the information on pages

Seite 3 - Specication

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1011Bracket installationInstall the four metal mounting brackets supplied onto the S

Seite 4 - Dimensions (mm)

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1012Fixing the unit to the frameThe Symmetry RDV3610 comes pre-assembled with the bu

Seite 5 - Location

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1013Flue installation - Rinnai ue kitsRinnai Symmetry RDV3610 ue kits have been ba

Seite 6 - To ceiling

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1014Flue installation - Rinnai ue kitsSymmetry RDV3610 horizontal ue kits and dime

Seite 7

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1015Flue installation - Rinnai ue componentsRDV3610 Flue Elbow 90° Bend (R3643)1651

Seite 8

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1016Flue installation - 45 degree offsetsFlue pipe (length and code) Offset (mm) Ris

Seite 9 - Installation guide overview

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1017Flue installation - general guidelinesEvery gas replace requires a ue system t

Seite 10 - 850 mm min

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1018Flue installation - general guidelinesFlue terminal locationsMust be compliant w

Seite 11

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1019Flue installation - vertical terminationFor vertical ue terminations with or wi

Seite 12 - Fixing the unit to the frame

ContentsWARNINGImproper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. For a

Seite 13 - Roof cowl (high wind)

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1020Flue installation - vertical terminationFor vertical ue terminations with two 9

Seite 14

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1021Flue installation - horizontal terminationFor horizontal ue terminations with a

Seite 15 - Elbow swivels 360 ° at base

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1022Gas connectionThe gas connection from the control valve is a ½ " BSP male 

Seite 16

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1023Flue restrictor installationThe ue restrictor is required to be tted in instal

Seite 17 - Combusble Material

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1024Log set installationThe log set (burn media) is packaged separately and consists

Seite 18

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1025Log set installationPlace the Top Log onto the recessed sections of the Left and

Seite 19 - Restrictor posion # 2

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1026Test pressures1. Turn on the gas and power supply to the unit. 2. Refer to the

Seite 20 - No restrictor

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1027Flame patternIt may take approximately two hours of operation for the logs to ac

Seite 21

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1028CladdingNon-combustible cladding must be installed directly above the re as sho

Seite 22 - Gas connection

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1029Fitting the frames and dress guardBefore tting the frames and/or dress guard en

Seite 23 - Flue restrictor installation

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-103Before installationUnpack the appliance and components and check for damage. DO N

Seite 24 - Log set installation

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1030CommissioningComplete the installation and commissioning checklist in the custom

Seite 25

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-1031Wiring diagram (11652-A)(BROWN)(RED)(RED)(WHITE)(BLUE)(RED)1211(BROWN)FUSE 3A 25

Seite 26 - Test pressures

Consumers: 0800 RINNAI (746 624)Installers: 0800 TO RINNAI (86 746 624)Address: 105 Pavilion Drive, Mangere, Auckland PO Box 53177, Auckland Air

Seite 27 - Flame pattern

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-104Dimensions (mm)31010907155108909955001060400149750775845

Seite 28 - Cladding

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-105LocationThe main points governing location are ueing and warm air distribution.

Seite 29

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-106ClearancesThe appliance must not be installed where curtains or other combustible

Seite 30 - Commissioning

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-107Mantels, surrounds, and hearthsHearthsA hearth is not necessary but can be used f

Seite 31 - Wiring diagram (11652-A)

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-108TV installation above a replaceIf installing a at screen TV above the re the m

Seite 32

Rinnai New Zealand Limited RDV3610 Installation Manual: 11658-E05-109Installation guide overviewBuild frame and complete electrical connection.This ov