Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Operation and Installation Manual
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Table of Contents ..................... 2
Consumer Safety Information ... 4
Operating Instructions ............... 6
Maintenance ........................... 11
Error Codes ............................ 12
Installation Instructions ........... 16
Consumer Support .................. 44
French Version ....................... 47
RL75i .................. REU-VB2528FFUD-US
RL94i .................. REU-VB2735FFUD-US
R98LSi ................ REU-VA3237FFU-US
R98LSi-ASME .... REU-VA3237FFU-ASME
Direct Vent Tankless Water Heater
FOR INDOOR APPLICATIONS ONLY
Register your product at www.rinnairegistration.com or
call 1-866-RINNAI1 (746-6241)
ANS Z21.10.3
CSA 4.3
If the information in these instructions is not
followed exactly, a fire or explosion may
result causing property damage, personal injury or death.
WARNING
The VB series (RL75i, and RL94i) are certified for
installation in manufactured (mobile) homes.
Seitenansicht 0
1 2 3 4 5 6 ... 71 72

Inhaltsverzeichnis

Seite 1 - WARNING

— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS

Seite 2 - Table of Contents

10 VB Series Indoor LS Manual Setting Controller to Mute To eliminate the beeps when keys are pressed or to turn the beeps back on,

Seite 3 - Specifications

VB Series Indoor LS Manual 11 WARNING Turn off the electrical power supply, the manual gas valve and the manual water control valve whenever

Seite 4 - Description of Operation

12 VB Series Indoor LS Manual Error Codes The Rinnai water heater has the ability to check its own operation continuously. If a fault occurs, an er

Seite 5

VB Series Indoor LS Manual 13 Code Fault Remedy 16 Over Temperature Warning Check for restrictions in air flow around unit and vent terminal. Ch

Seite 6 - Operating Instructions

14 VB Series Indoor LS Manual Trouble Shooting for Common Issues I don’t have any hot water when I open the tap. Make sure there i

Seite 7

VB Series Indoor LS Manual 15 Water HeaterPressure Relief Valve3/4" Ball Valve3/4" UnionCheck ValveSPressure RegulatorCirculating PumpSo

Seite 8 - (Voice Prompt)

16 VB Series Indoor LS Manual Only properly trained and qualified installers should install this appliance. The warranty may be voided due to impro

Seite 9

VB Series Indoor LS Manual 17 Clearances from Appliance 1. Identify the installation location and confirm that the installation w

Seite 10

18 VB Series Indoor LS Manual Gas Piping General Instructions • A manual gas control valve must be placed in the gas supply l

Seite 11 -

VB Series Indoor LS Manual 19 Pipe Sizing Procedure - Example 1. For some tables, you will need to determine the cubic feet per hour of gas requi

Seite 12 - Error Codes

2 VB Series Indoor LS Manual Specifications ... 3 Consumer Safety Information Safety Definitions .

Seite 13

20 VB Series Indoor LS Manual Isolation Valves and Pressure Relief Valve (RL75i and RL94i) Water Piping The isolation valves p

Seite 14

VB Series Indoor LS Manual 21 • A manual water control valve must be placed in the water inlet connection to the Rinnai water heater before it is

Seite 15

22 VB Series Indoor LS Manual If the water heater is not going to be used during a period of possible freezing weather, it is recommended that the w

Seite 16 - Installation Instructions

VB Series Indoor LS Manual 23 Pressure Relief Valve3/4" Ball Valve3/4" UnionCheck ValveSPressure RegulatorCirculating PumpSolenoid Valve

Seite 17

24 VB Series Indoor LS Manual Recommended Piping for Basic Installation GasSupply3/4"ColdWaterSupplyLine3/4" Hot Water Supply

Seite 18

VB Series Indoor LS Manual 25 Recommended Piping for Circulation Systems Pressure Relief Valve3/4" Ball Valve3/4" UnionCheck

Seite 19

26 VB Series Indoor LS Manual Venting Instructions • This water heater is a direct vent water heater and therefore is certified

Seite 20

VB Series Indoor LS Manual 27 Example: If you have one elbow then your maximum vent length is 35 feet (10.7 m). If your actual length is greater

Seite 21 - Freeze Protection

28 VB Series Indoor LS Manual Vent Products Manufacturer Product Parts Rinnai/Ubbink Rolux Vent System Heat-Fab Saf-T Vent SC system Metal-Fab C

Seite 22

VB Series Indoor LS Manual 29 Flue Terminal Clearances (ANS Z21.10.3, CSA 4.3) INSIDECORNER DETAI LFIXEDCLOSEDOPERABLEFIXEDCLOSEDOP

Seite 23 - Water Heater

VB Series Indoor LS Manual 3 Specifications Rinnai is continually updating and improving products. Therefore, specifications are subject to chang

Seite 24

30 VB Series Indoor LS Manual 24"V Additional Clearances - Vent Terminal Local codes supersede these clearances. • Avoid termin

Seite 25

VB Series Indoor LS Manual 31 Flue Installation - Concentric Venting (RL75i, RL94i) 3 in (75 mm) minimum Condensate Trap Vertical Terminat

Seite 26

32 VB Series Indoor LS Manual Air Intake Assembly The air intake system consists of a field supplied 4 inch diameter stainless steel, Schedule 40 PV

Seite 27 - Maximum Vent Length

VB Series Indoor LS Manual 33 Vertical Terminations The air intake requires a return bend or two 90º elbows to prevent entry of rain. SLOPE INT

Seite 28

34 VB Series Indoor LS Manual High Altitude Installations 0-2000 ft (0-610 m) 2001-5200 ft (610-1585 m) 5201-7700 ft (1585-2347 m

Seite 29

VB Series Indoor LS Manual 35 The conversion shall be carried out by a manufacturer’s authorized rep-resentative, in accordance with the require

Seite 30 - 60"

36 VB Series Indoor LS Manual Temperature Controller Installation • The controller should be out of reach of small children. • A

Seite 31

VB Series Indoor LS Manual 37 Temperature Controller Installation 1. Determine a suitable location for the controller. 2. Make

Seite 32

38 VB Series Indoor LS Manual Operating Instructions FOR YOUR SAFETY READ BEFORE OPERATING A. This appliance does not have a pil

Seite 33 - MINIMUM 1/4" PER FOOT

VB Series Indoor LS Manual 39 0.01.02.03.04.05.06.07.08.09.00.00 255075100125150Technical Data Pressure Drop Curve Outlet Flo

Seite 34

4 VB Series Indoor LS Manual WARNING Safety Behaviors and Practices • Keep the area around the appliance clear and free fro

Seite 35 - CANADA ONLY

40 VB Series Indoor LS Manual Space Heating If the water heater is to be used for both water (potable) heating and space heatin

Seite 36 - Controllers

VB Series Indoor LS Manual 41 Dimensions DIM DESCRIPTION RL75i RL94i in (mm) R98LSi R98LSi-ASME in (mm) A Width 14 (355.6

Seite 37

42 VB Series Indoor LS Manual Ladder Diagram (for RL75i and RL94i) For the R98LSi and R98LSiASME models see the next page. 5A (FUSE)

Seite 38 - Manual Valve

VB Series Indoor LS Manual 43 Ladder Diagram (for R98LSi and R98LSi-ASME) RELAY 1IGFROST SENSINGSWITCHANTI-FROST HEATERIGNITIONCOMBUSTIO

Seite 39

44 VB Series Indoor LS Manual What is covered? This Warranty covers any defects in materials or workmanship when the product is installed and operat

Seite 40

VB Series Indoor LS Manual 45 What will Rinnai do? Rinnai will repair or replace the covered product or any part or component that is defective in

Seite 41

46 VB Series Indoor LS Manual NOTICE BEFORE INSTALLATION Rinnai direct-vent appliance must be installed by a state qualified or licensed contractor

Seite 42 - 5A (FUSE)

Manuel – Chauffe-eau d’intérieur série VB LS 47 — Ne pas entreposer ni utiliser d'essence ou ni d'autres vapeurs ou liquides inflammabl

Seite 43

48 Manuel – Chauffe-eau d’intérieur série VB LS Comportements et pratiques de sécurité Réglage de température Instruc

Seite 44 - Consumer Support

Manuel – Chauffe-eau d’intérieur série VB LS 49 Plages de température avec un contrôleur de température Ce chauffe-eau va tenter de fourn

Seite 45

VB Series Indoor LS Manual 5 Temperature Controller MC-91-1US & MCC-91-1US The MC-91 controller is the standard temperature

Seite 46 - State Regulations

50 Manuel – Chauffe-eau d’intérieur série VB LS AVERTISSEMENT Coupez l'alimentation électrique, et fermez l'arrivée de gaz et d'

Seite 47 - Chauffe-eau d’intérieur sans

Manuel – Chauffe-eau d’intérieur série VB LS 51 Seuls des installateurs qualifiés avec une formation adéquate peuvent installer cet appareil. La g

Seite 48 - Brûlure

52 Manuel – Chauffe-eau d’intérieur série VB LS Écartements par rapport à l'appareil 1. Identifiez l'emplacement d&apo

Seite 49

Manuel – Chauffe-eau d’intérieur série VB LS 53 Installation à altitude élevée Micro-commutateur 0-2000 ft (0-610 m) 2001-520

Seite 50 - INCORRECT

54 Manuel – Chauffe-eau d’intérieur série VB LS Tuyauterie d'eau Valve à Bille / Valve de dégagement de pression (RL75i, RL9

Seite 51

Manuel – Chauffe-eau d’intérieur série VB LS 55 • Une vanne manuelle de coupure d'eau doit intercalée sur la conduite en amont sur l'arr

Seite 52

56 Manuel – Chauffe-eau d’intérieur série VB LS Tuyauterie recommandée pour installation de base GasSupply3/4"ColdWaterSupplyLine3/4&

Seite 53

Manuel – Chauffe-eau d’intérieur série VB LS 57 Instructions de ventilation • Les terminaisons verticales doivent incorpor

Seite 54

58 Manuel – Chauffe-eau d’intérieur série VB LS Nombre de coudes à 90° 0 1 2 3 4 5 6 41 ft 1 (12.5 m) 35 ft 2 (10.7 m) 29 ft 3 (8.8 m) 23 f

Seite 55

Manuel – Chauffe-eau d’intérieur série VB LS 59 Manufacturer Product Adaptateur d'appareil Terminaison Vertical Terminaison horizontale Term

Seite 56 - Chauffe-eau

6 VB Series Indoor LS Manual Features Available on Temperature Controllers Operating Instructions Features MC-91 MC-100 BC-100 MC-502 Des

Seite 57 - AVERTISSEMENT

60 Manuel – Chauffe-eau d’intérieur série VB LS INSIDECORNER DETAI LFIXEDCLOSEDOPERABLEFIXEDCLOSEDOPERABLEBBBAJBMCFBBEDLGAHKIRéf. Description I

Seite 58 - Switch No

Manuel – Chauffe-eau d’intérieur série VB LS 61 Installation de conduit de cheminée (RL75i, RL94i) 3 in (75 mm) minimum Condensate Trap Ter

Seite 59

62 Manuel – Chauffe-eau d’intérieur série VB LS Ensemble de prise d'air Le système d'admission d'air consiste en un tuyau de fournit

Seite 60

Manuel – Chauffe-eau d’intérieur série VB LS 63 Terminaisons verticales L'admission d'air nécessite un coude en U ou deux couses à 90° p

Seite 61

64 Manuel – Chauffe-eau d’intérieur série VB LS Instructions d'utilisation À LIRE AVANT LA MISE EN SERVICE POUR VOTRE SÉCURI

Seite 62 - Terminaisons horizontales

Manuel – Chauffe-eau d’intérieur série VB LS 65 Diagramme en escalier (RL75i, RL94i) PHASE NEUTRE CONTACT DE DÉTECTION DE GEL

Seite 63

66 Manuel – Chauffe-eau d’intérieur série VB LS Diagramme en escalier (R98LSi, R98LSiASME) RELAY 1IGFROST SENSINGSWITCHANTI-FROST HE

Seite 64

Manuel – Chauffe-eau d’intérieur série VB LS 67 Support à la clientèle Qu'est-ce qui est couvert ? Cette garantie couvre tous défauts dus au

Seite 65

68 Manuel – Chauffe-eau d’intérieur série VB LS Que fait Rinnai pour exercer la garantie ? Rinnai va réparer ou remplacer le produit, ou toute part

Seite 66

VB Series Indoor LS Manual 69 Notes

Seite 67 - Support à la clientèle

VB Series Indoor LS Manual 7 How to Set the Temperature While any hot water is being provided, the temperature setting can only be

Seite 68

70 VB Series Indoor LS Manual Notes

Seite 69

VB Series Indoor LS Manual 71 Notes

Seite 70

U287-1930(00)Printed in JapanVB2528FFUVB2735FFUVA3237FFU060 00012 32191 3

Seite 71

8 VB Series Indoor LS Manual Suggested temperatures are • Kitchen 120 ºF (49º C) • Shower 98 - 110 ºF (37 - 43 ºC) • Bath Fill 102 - 110 ºF (3

Seite 72 - VA3237FFU

VB Series Indoor LS Manual 9 Setting the Water Volume Using the Water Smart / Bath Fill Function Overview This function is exclusive

Kommentare zu diesen Handbüchern

Keine Kommentare